GelSight Mini / original DIGIT matched-task records RoboSkin.ai template version: 2026-10-25 Guide: https://roboskin.ai/guides/gelsight-vs-digit#comparison-records PURPOSE AND EVIDENCE BOUNDARY These blank records help plan and document a comparison on your own robot. They contain no sensor measurements, simulated results or device ranking. RoboSkin.ai has not bench-tested GelSight Mini or original DIGIT for this guide. This is a proposed recording method, not a certified benchmark or safety test. The CSV files do not execute code, calculate statistics or upload data. The scope is GelSight Mini and original DIGIT. Keep Digit 360, DIGIT Pinki and other GelSight devices in separate, explicitly named evaluations. Hardware version, specimen, software and mounting differences matter even within one product name. A common task alone does not make all conditions comparable. FILES AND ORDER 1. Open gelsight-digit-comparison-protocol.csv in a spreadsheet or CSV editor. Fill the two value columns. Match the study ID, task, objects, success rule and controller budget where possible. Describe all remaining differences. Freeze the protocol revision before examining evaluation outcomes. 2. Add one row to gelsight-digit-comparison-trials.csv for EVERY attempted trial, including failures and exclusions. Reuse the exact study, condition and calibration IDs. A trial is an attempted task, not an individual frame. Keep raw evidence and calibration files; use stable local paths or URIs. 3. If evaluating slip, use gelsight-digit-comparison-slip-events.csv for each independently annotated onset and each unmatched detector alarm. Join it to the trial log using study_id + condition_id + trial_id. The event log is optional for tasks that do not evaluate slip. 4. Summarize only after checking missing data, protocol deviations, trial counts and clock alignment. Keep separate results for different conditions and for the held-out groups declared in the protocol. The trial and event files intentionally have headers only. Add your own rows; no apparent zero values or prefilled successes are supplied. Blank means not measured or not entered. A blank is never a zero. Use not_applicable only when the field does not apply and put the reason in notes. Use numeric 0 only for an observed zero. Preserve unknown outcomes as unknown and explain them. Quote CSV text containing commas, quotes or line breaks using your editor's CSV export. Do not replace raw evidence with a summary spreadsheet. PROTOCOL DETAILS Give each configuration a unique condition_id. Record the sensor unit, gel state, unloaded reference, software/model revisions, actual robot/hand, mount and cable path. Create a new condition when changing an acquisition mode, model or gel affects the comparison; retain the relationship to the old one. Do not silently overwrite a calibration record. Separate three kinds of evidence: - Configured: requested resolution, FPS, exposure, controller budget. - Observed: received frames, timestamps, independently labeled contact, robot-task outcomes and reference measurements. - Derived: reconstructed depth, force estimates, detector decisions and statistics calculated from the observed evidence. An RGB stream is not a calibrated force measurement. Set the target quantity, reference, unit and validation range before claiming depth or force accuracy. Record the independent reference's uncertainty and repeated-contact error. Camera pixel count and requested FPS are not task accuracy or control latency. TRIAL FIELD DEFINITIONS Identifiers: - study_id / protocol_revision / condition_id: keys from the protocol. - trial_id: unique within study and condition; do not reuse after an exclusion. - session_id: collection session used to trace time, wear or calibration drift. - trial_order: actual execution order; retain the planned ordering separately. - object_id / evaluation_group: object and declared split or held-out group. - initial_conditions: actual setup and units; record deviations from the plan. - calibration_id: version applied to the data or not_applicable with a reason. - raw_evidence_path: raw stream/robot log plus metadata needed to interpret it. - slip_annotation_path: independent annotation or reference recording. Status and counts: - trial_status: completed, excluded, or incomplete. Completed means the trial reached an outcome; it can be a task failure. Do not label failure excluded merely to improve the success rate. - exclusion_reason: required for an exclusion; reference the predeclared rule. - frames_received: received frames in the measurement window, including invalid frames if they arrived. Define the window in the protocol. - invalid_frames: received frames failing the declared validity rule. - observed_stream_rate_hz: measured received rate using the protocol's clock and counting convention; never copy the requested or advertised FPS here. - frame_gap_count: gaps under the declared rule. A timestamp gap is not proof of an exact number of lost frames; retain the source timestamps. Timing: - loop_delay_ms: measured delay between the exact start and end events in the protocol. A host receive timestamp cannot establish earlier exposure time. - loop_delay_statistic: the actual statistic, such as median or p95, matching the protocol. Do not compare one device's median with another's maximum. - loop_delay_sample_count: number of latency observations behind that value. - clock_uncertainty_ms: remaining uncertainty after mapping clocks; do not enter zero just because the devices share a host. - non_slip_observation_s: independently labeled non-slip exposure used for false-alarm reporting; state any excluded time in the protocol. Outcomes: - task_success: true, false, or unknown under the predeclared end-to-end rule. - outcome_reason: evidence for success/failure/unknown, including partial completion, drops, jams or a time-limit failure as appropriate to the task. - intervention_count: counted under the protocol's definition. Include its effect on success in outcome_reason; do not silently count assisted trials as unassisted successes. - measurement_uncertainty: quantity, unit, method and unresolved limits; reference a fuller calibration/analysis file when needed. - protocol_deviation / notes: deviations, missing measurements and reasons. OPTIONAL SLIP EVENT FIELDS AND MATCHING Define a physical onset criterion using an independent reference, an alarm matching window, and treatment of early or duplicate alarms BEFORE evaluating the detector. Match at most one alarm to each physical event. Store each additional unmatched alarm as its own false_alarm row under the frozen rule. Do not use the detector being evaluated to generate its own ground truth. event_class is one of: - detected: independently confirmed onset with one matching detector alarm. - missed: independently confirmed onset with no alarm in the matching window. - false_alarm: an alarm without a matching onset under the declared rule. - unresolved: reference or timing evidence is insufficient; explain why. Use event_id to identify one row. reference_evidence_path identifies the source used for classification. in_non_slip_window is true, false or unknown according to the independently labeled non-slip intervals counted in the trial log. It distinguishes false alarms during non-slip exposure from unmatched or duplicate alarms outside that exposure. reference_clock names the common time basis. onset_lower_s and onset_upper_s bound the reference onset on that clock. Use a single value in both fields only when the measurement supports it. Keep temporal resolution and annotation ambiguity visible; an image frame does not establish an infinitely precise onset time. detector_event_s is the alarm time mapped to the SAME clock. Leave it blank for a missed event. Leave onset bounds blank for an unmatched alarm. Leave delay fields blank for missed, false_alarm and unresolved rows; they do not have a matched detection delay. Keep detector events before the onset if the matching rule permits them; do not clip negative delays to zero. clock_uncertainty_ms records remaining clock-mapping uncertainty. annotation_uncertainty_ms describes additional annotation uncertainty beyond the onset interval, if present. Record the method and interpretation in notes; do not automatically add quantities with incompatible uncertainty definitions. For a matched detected event with a shared clock: delay_lower_ms = 1000 * (detector_event_s - onset_upper_s) delay_upper_ms = 1000 * (detector_event_s - onset_lower_s) These bound delay from the onset interval only. They are not confidence intervals and do not include extra clock/annotation uncertainty automatically. Leave them blank if clock alignment is unknown and explain unresolved_reason. Retain raw timestamps and the mapping used for any later recalculation. REPORTING WITHOUT HIDING FAILURES For each condition and held-out group, report attempted, excluded and evaluable trial counts. State the denominator for task success and show the count of unknown/incomplete outcomes. Report unassisted and assisted outcomes according to the declared intervention rule. Do not average partial stages and relabel that number as end-to-end completion. For slip detection, report detected and missed reference events together. Recall = detected / (detected + missed), only if that denominator is positive. Precision = detected / (detected + false_alarm), only if positive and using the frozen matching rule. Report unresolved rows separately. False alarms per non-slip minute = false_alarm rows with in_non_slip_window=true divided by (non_slip_observation_s / 60), only with positive, independently labeled non-slip exposure. Count alarms and exposure over the same evaluation window. An undefined denominator is not zero. Summarize delay only for matched detections and report how many events were missed. This is conditional detection delay, not latency for all events. Report recovery/task success separately; detecting slip does not establish that the controller prevented a drop. Capture-to-controller delay, physical actuator response and slip-onset-to-detection delay measure different events. Choose an uncertainty interval appropriate to the independent sampling unit. Adjacent frames and repeated contacts from one object/session are correlated; do not count them as independent robot trials. Name the interval/resampling method, unit, sample count and aggregation. State when object/session/unit coverage is too limited to support a wider transfer claim. SOURCE BASIS The recording structure is RoboSkin.ai's proposed method. It operationalizes the guide's existing matched-task evaluation plan; it is not an official GelSight or DIGIT benchmark. The following pinned primary documentation was re-read on 2026-10-25 for the acquisition and derived-output boundaries: DIGIT interface, revision 87a28bbf2beee8008a5308e9a12d72e1bc4fefb9: https://github.com/facebookresearch/digit-interface/blob/87a28bbf2beee8008a5308e9a12d72e1bc4fefb9/README.md Supports serial-based identification, get_frame(), the documented default stream and explicit stream configuration. It does not establish a successful run or the performance of your unit. GelSight robotics, revision 321d6a22da64529138ff10237335038fd8c5189f: https://github.com/gelsightinc/gsrobotics/blob/321d6a22da64529138ff10237335038fd8c5189f/README.md The FAQ separates reconstruction examples and camera resolution from accuracy, describes learning force from height displacement, and discusses gel damage. It does not supply a matched comparison with original DIGIT. Related workflows: https://roboskin.ai/guides/tactile-sensor-calibration https://roboskin.ai/guides/tactile-sensor-benchmark-robot-manipulation https://roboskin.ai/guides/slip-detection-robot-hand